Call Us:IRL +353 (0)61-335844 / UK +44 (0)28 30833808

Food & Water Safety

  • UHT and ESL Beverage Testing The 3M™ Microbial Luminescence System (MLS) is a rapid method for release testing of Ultra High Temperature (UHT) and Extended Shelf Life (ESL) processed products. Following a 2 to 3 day pre-incubation of the product sample, simply pipette 50 µL of the pre-incubated sample into a well of the microplate. Place the microplate on the 3M MLS II instrument and select the appropriate assay within the software. The instrument provides real-time results in 27 minutes or less. With traditional agar methods, not only do you have to pre-incubate sample containers, you then have to wait 2 to 5 days for the microorganisms to grow on the plate. The 3M Microbial Luminesce System eliminates the second incubation period, allowing you to release product 2 to 5 days faster. That means you can reduce inventory storage space and cost, generate faster inventory turns, increase cash flow and be more flexible and responsive to customer needs. Reassuring Reliability. Using bioluminescence technology, the 3M Microbial Luminescence System detects ATP (adenosine triphosphate), an energy molecule universally present in all living organisms. This allows the 3M MLS to have faster time-to-result than traditional pH or agar tests, and more reliably detect a broad range of microorganisms than traditional methods. With the 3M MLS UHT Beverage Screen Kit, a wide variety of UHT and ESL products can be tested such as dairy products (milk, flavored milk, creamers, ice cream mixes), dairy substitutes (soy, rice, almond and coconut milks), juices (orange, apple, peach, grape, tomato), caffeinated beverages, smoothies (formulated with milk and juice), infant/medical nutrition (baby formula, nutrition shakes), coconut water, soups and broths.
  • Aerobic Count results as soon as 48 hours The 3M™ Petrifilm™ Aerobic Count Plate is a time-saving, sample-ready plate designed to determine total aerobic bacteria populations. A built-in grid facilitates counting colonies, helping to provide fast, precise and consistent results. Each 3M Petrifilm Aerobic Count Plate contains a water-soluble gelling agent, nutrients and indicator — all the components needed for microbial growth with no agar preparation required. The 3M Petrifilm Aerobic Count Plate provides total aerobic count in as little as 48 hours. A red indicator dye in the plate colors all colonies red for better contrast and easier colony counting. The red colonies are also easily distinguished from opaque food particles that can cause confusion when using other plating methods. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality. In addition, 3M Petrifilm Aerobic Count Plates can be used to aerobically or anaerobically enumerate lactic acid bacteria in food and environmental samples.  
  • Detects coliforms in bottled water 3M™ Petrifilm™ Aqua Coliform Count Plates are sample-ready media plates used to measure coliform levels and provide reliable test method for bottled water. Each plate contains a water-soluble gelling agent, nutrients and indicators in a dry, shelf-stable format. The indicator dye colors all colonies red, and the top film traps the gas produced by the coliforms. Gas trapped around red coliform colonies indicates confirmed colonies. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.
  • Detects heterotrophic bacteria in bottled water 3M™ Petrifilm™ Aqua Heterotrophic Count Plates provide fast, accurate results in enumerating heterotrophic bacteria in the bottled water industry. These plates are used for the enumeration of heterotrophic bacteria in bottled water industries. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.    
  • Enumeration of yeast and mold in bottled water 3M™ Petrifilm™ Aqua Yeast and Mold Count Plates are a sample-ready culture medium system which contain nutrients supplemented with antibiotics, a cold-water-soluble gelling agent, and an indicator that facilitates yeast and mold enumeration. These plates are used for the enumeration of yeast and mold in bottled water industries. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.    
  • Coliform results in 24 hours 3M™ Petrifilm™ Coliform Count Plates provide a cost-effective, convenient and reliable method for testing equipment, raw materials, food products and manufacturing environmental samples. The 3M Petrifilm Coliform Count Plate is a sample-ready-culture-medium system which contains Violet Red Bile (VRB) nutrients, a cold-water-soluble gelling agent, and a tetrazolium indicator that facilitates colony enumeration in food and beverage samples. These plates provide total coliform count information with confirmed results in just 24 hours. By eliminating subsequent confirmation steps required with most traditional reference methods, the 3M Petrifilm Coliform Count Plates can help increase productivity and reduce overall lab costs. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.
  • Confirmed E. coli results in 24-48 hours 3M™ Petrifilm™ E. coli/Coliform Count Plates provide a cost-effective, convenient and reliable method for testing equipment, raw materials, food products and manufacturing environmental samples. The 3M Petrifilm E. coli/Coliform Count Plate is a sample-ready-culture-medium system which contains Violet Red Bile (VRB) nutrients, a cold-water-soluble gelling agent, an indicator of glucuronidase activity (BCIG), and a tetrazolium indicator that facilitates colony enumeration in food and beverage samples. These plates provide both E. coli and total Coliform Count information with confirmed results in just 24-48 hours. By eliminating subsequent confirmation steps required with most traditional reference methods, the 3M Petrifilm E. coli/Coliform Count Plates can help increase productivity and reduce overall lab costs. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.  
  • Enumeration of Enterobacteriaceae in the food, beverage and bottled water industries 3M™ Petrifilm™ Enterobacteriaceae Count Plates provide a cost-effective, convenient and reliable method for testing equipment, raw materials, food products and manufacturing environmental samples and bottled water testing 3M™ Petrifilm™ Enterobacteriaceae Count Plates enable you to quickly determine potential sources of contamination. This plate enumerates all coliforms as well as potential pathogens such as Salmonella, Shigella and Yersini. The 3M Petrifilm Enterobacteriaceae Count Plate can also be read using the 3M™ Petrifilm™ Plate Reader which provides consistent, fast, automated reading and recording of results of 3M Petrifilm Plates (Aerobic Count, Rapid Aerobic Count, Coliform Count, E. coli/Coliform Count, Enterobacteriaceae Count and Select E. coli Count ) in 4 seconds. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.    
  • Rapid results in 27-31 hours from sample collection 3M™ Petrifilm™ Environmental Listeria Plates detect the presence of Listeria in environmental samples. A sample-ready culture medium containing selective agents, nutrients, a cold water-soluble gelling agent and a chromogenic indicator. This is designed to analyse environmental samples and help increase the efficiency of monitoring plant sanitation.
  • Detect the presence of Listeria in environmental samples 3M™ Petrifilm™ Environmental Listeria Plates detect the presence of Listeria in environmental samples. A sample-ready culture medium containing selective agents, nutrients, a cold water-soluble gelling agent and a chromogenic indicator. This is designed to analyze environmental samples and help increase the efficiency of monitoring plant sanitation. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.
  • Coliform results in 24 hours The 3M™ Petrifilm™ High-Sensitivity Coliform Count Plate accommodates 5 mL samples and detection of low levels of confirmed coliforms in 24 hours. This allows a 1-coliform-per-gram sensitivity if a 1:5 dilution of product is made. A 2-coliform-per-gram sensitivity is achieved if a 1:10 dilution is used. Whether testing milk, ice cream, cheese, or other food products, testing labs can benefit from the labor savings of 3M Petrifilm Plates. These plates reduce overall testing costs and allow producers to easily conform to higher sensitivity standards. 3M Petrifilm High-Sensitivity Coliform Count plates may be especially well-suited for use in facilities producing dairy products, where regulations and strict internal quality standards demand a high-sensitivity test that can deliver results quickly and accurately. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.
  • Introducing the first self-contained anaerobic plates for lactic acid bacteria testing The 3M™ Petrifilm™ Lactic Acid Bacteria Count Plate is a time-saving, sample-ready plate designed to determine total lactic acid bacteria populations in food and environmental samples. Every day, food processors, retailers and consumers are forced to throw out food spoiled with lactic acid bacteria. These normally useful bacteria can cause undesirable changes to ready-to-eat meats and seafood, dressings and sauces, vegetables and many other processed foods. This not only contributes to food waste and costly recalls, but can also damage your brand reputation. 3M science brings you a better way to test for lactic acid bacteria in your food products, raw materials and production environment without the hassle of traditional agar methods – 3M™ Petrifilm™ Lactic Acid Bacteria Count Plates. These ready-to-use plates simplify the testing process and give accurate results in less time, helping you reduce waste, minimize recalls and protect your reputation in the marketplace. Anaerobic made easy. Now you can get true anaerobic results using standard aerobic incubation conditions. The self-contained anaerobic environment in this plate enhances the recovery of lactic acid bacteria, providing fast, accurate results for effective control of product quality and shelf life. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardised and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.
  • 3M™ Petrifilm™ Plate Reader Advanced
    3M Food Safety Lab Automation—moving food testing forward There's no slowing down with automated 3M™ Petrifilm™ Plate enumeration using the 3M™ Petrifilm™ Plate Reader Advanced. It’s time to advance the efficiency of your lab by automating the imaging, interpretation and tracking of results. This system achieved up to 94% reduced time to enumerate 3M™ Petrifilm™ Plates (observed on the 3M™ Petrifilm™ Aerobic Count Plate with High Counts). The 3M™ Petrifilm™ Plate Reader Advanced is a compact instrument that automates the enumeration of 10 different 3M™ Petrifilm™ Plates and the 3M™ Petrifilm™ Staph Express Disk to enhance laboratory productivity and ensure accurate, consistent readings. Results are stored in the 3M™ Petrifilm™ Plate Manager Software for data analysis. The 3M™ Petrifilm™ Plate Reader Advanced enumerates 10 different 3M™ Petrifilm™ Plates: Rapid Aerobic Count, Rapid Coliform Count, Rapid E. coli/Coliform Count, Rapid Yeast and Mold Count, Aerobic Count, Coliform Count, Enterobacteriaceae Count, E. coli/Coliform Count, Select E. coli Count, Staph Express Count and Staph Express Disk. Following incubation, 3M Petrifilm Plates can be easily fed into the 3M Petrifilm Plate Reader Advanced where each plate is imaged and enumerated via onboard fixed artificial intelligence in less than six seconds. Each 3M Petrifilm Plate artificial intelligence network was trained and validated with a wide assortment of food matrices to ensure accurate plate enumeration. The 3M™ Petrifilm™ Plate Manager Software utilises a simple and streamlined user interface to collect, store, and report 3M Petrifilm Plate results. The system recognises 10 barcode symbologies which enables users to easily map details such as technician, food type, and dilution, rather than transcribing by hand. Results can be exported to a user’s Laboratory Information Management System (LIMS) and other reporting tools. Additionally, the 3M Petrifilm Plate Manager Software allows users to access results from multiple PCs that are connected to a company intranet.
  • Aerobic Count results as soon as 24 hours 3M™ Petrifilm™ Rapid Aerobic Count Plates feature technology that facilitates colony enumeration in just 24 hours for most food matrices / environmental samples and resists distortion caused by spreader colonies. Aerobic count bacteria are present in a variety of food matrices and serve as indicators for food spoilage. Getting accurate aerobic bacteria counts in your raw materials, finished product and production environment are critical to making time sensitive decisions that impact process control, cleaning decisions and, ultimately, product quality and safety. 3M™ Petrifilm™ Rapid Aerobic Count Plates are a sample ready, culture medium system, which contain nutrients, a cold water soluble gelling agent, and a dual sensing indicator technology that facilitate colony enumeration in 24 hours for most food matrices and environmental samples. Proven as reliable as the SMA plate method, 3M Petrifilm Rapid Aerobic Count Plates help agar users avoid costly retesting and delayed results due to interpretation issues caused by spreader colonies. The 3M Petrifilm Rapid Aerobic Count Plate can also be read using the 3M Petrifilm Plate Reader which provides consistent, fast, automated reading and recording of results of 3M Petrifilm Plates (Aerobic Count, Rapid Aerobic Count, Coliform Count, E. coli/Coliform Count, Enterobacteriaceae Count and Select E. coli Count ) in 4 seconds. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.
  • Coliform results in 6 - 14 hours 3M™ Petrifilm™ Rapid Coliform Count Plates are designed to provide fast, accurate results in detecting coliform contamination. Coliform colonies may begin to appear at 6 hours of incubation as discrete yellow zones indicating colony forming units (CFUs). Presumptive coliforms may be be recorded at 14 hours. Confirmed coliforms will appear as red colonies associated with gas after 8 – 24 hours of incubation. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.
  • E. coli and coliform results in 18-24 hours 3M™ Petrifilm™ Rapid E. coli/Coliform Count Plates provide a cost-effective, convenient and reliable method for testing equipment, raw materials, food products and manufacturing environmental samples. The 3M™ Petrifilm™ Rapid E. coli / Coliform Count (REC) Plate is a selective and differential sample ready culture medium system which contains proprietary nutrients, a cold water soluble gelling agent, 5 bromo 4 chloro 3 indolyl D glucuronide (BCIG) an indicator of glucuronidase activity, and a tetrazolium indicator that facilitates colony enumeration. The 3M Petrifilm REC Plate is used for the enumeration of Escherichia coli (E. coli) and coliforms in the food and beverage industries. These plates provide both E. coli and total coliform count information with confirmed in just 18 24 hours. By eliminating subsequent confirmation steps required with most traditional reference methods, the 3M Petrifilm Rapid E. coli/Coliform Count Plates can help increase productivity and reduce overall lab costs.
  • Yeast and mold results in 48-72 hours 3M™ Petrifilm™ Rapid Yeast and Mold Count Plate features a new indicator technology that makes colonies easier to interpret. This sample-ready-culture-medium system provides results in as little as 48 hours of incubation time. Yeast and molds can grow in a wide range of conditions in raw materials, finished products and production environments, making them difficult to control. The 3M™ Petrifilm™ Rapid Yeast and Mold Count Plate method is faster and easier than the traditional agar method that requires a five day incubation period. This plate features a new indicator technology that makes colonies easier to interpret. This sample ready culture medium system provides results in as little as 48 hours of incubation time. Proven as reliable as the DRBC and DG 18 spread plate methods as well as the acidified PDA and YGC agar pour plate methods. 3M Petrifilm Rapid Yeast and Mold Count Plates also enhance productivity by eliminating the inoculation of multiple spread plates, the addition of antibiotics or tartaric acid, and the agar preparation process altogether. Faster results provide more time to monitor processes and ensure tighter process controls along with a higher quality product.
  • Staphylococcus aureus results in 24 hours 3M™ Petrifilm™ Staph Express Count Plates provide Staphylococcus aureus results. S. aureus appears as distinctive red-violet colonies. Other colonies have to be checked using the Staph express disk. If you encounter high background flora in your staph testing, the 3M™ Petrifilm™ Staph Express Disk can be used to identify Staph aureus from all suspect colonies. The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.
  • Yeast & Mould results in 3-5 days This 3M Petrifilm Yeast and Mold Count Plate is a sample-ready-culture medium system which contains nutrients supplmented with antibiotics, a cold-water-soluble gelling agent, and an indicator that facilitates yeast and mold enumeration. Yeasts are easily differentiated from molds on the plate:
    • Yeasts are typically indicated by small, blue-green colonies with defined edges and no foci.
    • Molds are indicated by large, variably-colored colonies with diffuse edges and center foci.
    The 3M Petrifilm Plate Advantage In today’s environment of heightened focus on food safety and increasingly stringent quality requirements, labs are under pressure to provide tests that are fast, reliable and consistently accurate. 3M Petrifilm Plates have demonstrated consistent performance that has been cited globally with more than 200 certificates, recognitions, validations, and peer-review publications. For more than 30 years, food safety professionals around the world have put their trust in 3M Petrifilm Plates. That’s because 3M Petrifilm Plates have streamlined, standardized and simplified the process of microbial quantitative indicator testing, improving productivity and helping ensure the highest levels of product quality.
  • Biotecon Diagnostics
    Allergens in food can cause serious, life-threatening symptoms, even in small quantities in sensitive individuals. Thus, safe detection of even the smallest traces of an allergen in a final product is important for quality assurance in the food industry.There are 14 food ingredients responsible for 90% of all food allergies. Following EU Directive 2007/68/EC or 2000/13/EC, they must be reported on the package label when present in a product. In some countries limits exist, such as in Switzerland, where it is 1,000 ppm. For the detection of major food allergens, BIOTECON Diagnostics offers real-time PCR kits. When used in combination with the Allergen RM 800 reference material, quantification is also possible.
  • Biotecon Diagnostics
    The foodproof® Animal Identification Kits detect specific animal species in food by real-time PCR. They enable the identification and differentiation of swine, cattle, sheep, horse, donkey, chicken and goat in food, such as raw and heated meat, animal feed and animal products. Animal species detection in food protects product purity. It also controls against fraud through verification of the animal species used in meat products.
  • Bentley Instruments
    Introducing the ILAS 4000 Robot The new ILAS 4000 robot is a unique solution to automate and standardise sample preparation for bacteria counters up to a maximum speed of 200 samples/hour. Fully refrigerated, samples are identified (RFID chips or barcode), homogenised, uncapped and analysed. The vials are automatically recapped after analysis and place back in their original tray position. Compatible with the BactoCount IBC Series: Bacteria & Somatic Cells Counter and alternative methods. The Standardisation Tray used for Laboratory Automation is compatible with the ILAS Robot.
  • Bentley Instruments
    Introducing the ILAS 3000 Robot The combination of the Bentley Instruments and high-tech robotics allows the complete automation and standardisation of the analytical chain and MSDs reduction. With the ILAS 3000 Robot, an operator can manage up to 3 lines simultaneously. Always with a goal of enhanced productivity and standardisation, this system analyses up to 600 samples/hour. Compatible with the Combi FTS Series: Infrared Analyser & Somatic Cells Counter and alternative methods. The Standardisation Tray used for Laboratory Automation is compatible with the ILAS Robot.
  • Bentley Instruments
    Real-Time enumeration of individual Bacteria & Somatic Cells in raw milk Automatic milk analysis at 200 samples/hour The BactoCount series (50, 100, 150, 200) uses flow cytometry for the real-time determination of total flora and somatic cells in raw milk up to a maximum speed of 200 analysis/hour. The high speed of this model makes it the ideal solution for mid to large size laboratories that need an easy to maintain, exceptionally fast bacteria counting system. The BactoCount IBC Series uses a proprietary process based on flow cytometry for the rapid, highly accurate, reliable and multiplex enumeration of individual bacteria and somatic cells in raw milk. The sampling, sequencing and identification of the sample vials are functions performed by the Autosampler.
    Microval

    Validated to be at least equivalent to the EN-ISO 4833-1:2013 and 4833-2:2013 reference methods for the enumeration of microorganisms in raw cow milk (Certificate n° 2013LR44)

    Compatible with the ILAS 4000 ROBOT: Automation System for Bacteria Counter
  • Bentley Instruments
    Real-Time enumeration of individual Bacteria & Somatic Cells in raw milk Semi-Automatic version up to 50 analysis/hour The new BactoCount IBCm 3.0 is a semi-automated instrument that uses a proprietary process based on next-generation flow cytometry for the rapid, highly accurate, reliable and multiplex enumeration of individual bacteria and somatic cells in raw milk. The rapid test for bacteria and somatic cells makes it the ideal solution for any processing plant or laboratory involved in the quality assessment of milk. The instrument offers multiplex applications thanks to its unique dedicated platform. Up to two applications can be run simultaneously on a given sample. The overall design of the instrument has also been designed to allow ease of access and maintenance. With this in mind, IBCm 3.0 embeds a new kinetic, self aligned flow cell mounting system. The BactoCount IBCm 3.0 can be equipped with a conveyor, automating the sampling at a maximum rate of 50 analysis/hour. The sampling, sequencing and identification of the sample vials are functions performed by the Autosampler.
    Microval

    Validated to be at least equivalent to the EN-ISO 4833-1:2013 and 4833-2:2013 reference methods for the enumeration of microorganisms in raw cow milk (Certificate n° 2013LR44)

    Compatible with the ILAS 4000 ROBOT: Automation System for Bacteria Counter
  • Certa Blue - Rapid Microbiology Technology CertaBlue™ - Rapid Microbiology
    Why wait? TECHNOPATH partners with CertaBlue for their rapid microbiology technology. CertaBlue is based on rapid detection of several metabolic processes that take place within the growing organism. The system can detect colour changes through highly sensitive optical sensors. All vials are ready to use, prefilled with media and equipped with CertaBlue sensors. In most cases, the vials can be inoculated with a non-diluted high volume sample. The CertaBlue vials contain an optical sensor, which can detect carbon dioxide as the universal indicator for microbial growth. The sensor is placed in the bottom of the vial, where it directly detects carbon dioxide changes. CertaBlue sensors are only permeable for gases. Liquids, dyed / heavily coloured products and other particles can’t falsify results. What can CertaBlue offer you:
    • Simplified test procedures
    • Ready-to-use vials including media and CertaBlue sensor
    • Test procedure consists of just adding your sample to the vial
    Rapid Results:
    • Results in hours instead of days
    • Real-time detection and early warning of positive samples
    • Ensures a quick and safe product release
    • Better recovery of injured and / or damaged microorganisms
  • Colifast
    Rapid, Automated and Remote Microbial Testing for Water and Food Safety Colifast ALARM™ is an electronic instrument for detecting indicator bacteria in drinking water using patented Colifast technology. 100 ml water samples are automatically collected at programmed intervals and analyzed for total coliforms, thermotolerant coliform bacteria or E. coli. In addition to performing rapid, online microbial water analysis, Colifast ALARM measures water turbidity. The system can automatically send results to control rooms / operators via LAN, digital signals or via mobile networks (SMS). The system can detect down to 1 cfu / 100 mL, and results are achieved within 6-14 / 15 hours. Technology The main components of Colifast ALARM are the incubator chamber, an injection pump system for fluid handling, and a detector system that includes wavelength-specific emitters combined with a spectrometer. Detection of down to 1 viable target bacteria is based on bacterial growth, group-specific enzyme activity and measured concentrations of a fluorescent product (ppb MU). An increase in the number of target bacteria means an increase in the amount of β-D-glucuronidase (E. coli-specific enzyme). The enzyme hydrolyses the growth medium substrate to MU (the fluorescent product) and β-D-glucuronic acid. Increased MU release gives increased fluorescence signal on the Colifast ALARM. Colifast growth medium contains inhibitors to prevent growth of non-coliforms. Colifast ALARM is verified by EPA's ETV program.
  • Colifast
    The Colifast At-Line Monitor – CALM is a fully automated early warning system for monitoring of coliforms and Pseudomonas aeruginosa in water. Detection time ranges from 2 to 12 hours. The technology is time-saving, cost-reducing, and environmentally friendly. Examples of CALM applications are monitoring of raw water, in-process water, waste water and recreational water. No laboratory facilities and minimal skills in microbiology are required to operate the instrument. The Colifast CALM is easily connected to the system computer or LAN interface. The patented Colifast growth media are supplied in Pre-filled Multi Well Trays™ and the flexibility of the system makes it easy to adapt to different applications. The CALM can perform parallel analysis of different target organisms. Depending on method and test frequency, the CALM needs monthly or weekly refilling of reagents. Technology The CALM instrument detects and quantifies E. coli, fecal or total coliform bacteria in water by fluorometric monitoring of β-glucuronidase activity (E. coli) or β-galactosidase activity (fecal and total coliforms). The detection of P. aeruginosa is based on substrate hydrolysis of aminopeptidase enzymes present in this bacterium. The Colifast technology is comprised of unique media formulations combined with instrument detection systems. The technology is covered by patents in numerous countries, with several international patents pending. Growth of other bacteria is stopped by inhibitors in the medium and by incubation of the samples at high temperature: Incubator temperatures for selection of thermotolerant coliform bacteria are 44 ° C and total coliforms / E. coli are 37 ° C. Method The instrument can perform one of two methods at a time. The Most Probable Number (MPN) method is based on the cultivation of bacteria. A certain volume is added to 4-6 wells of growth medium and the bacterial number is determined from how many of the wells that gave growth after the incubation period (11-12 hours). For the results to be as accurate as possible, it is therefore important that the samples taken on a given source usually give a mixture of positive and negative results. The rapid method is also a quantitative method, which is based on the enzyme activity of the bacteria present in the water sample. It provides response after 75-115 min and is suitable for water sources where major contamination events can occur. The CALM is a flexible instrument. This means that the instrument can be adapted to different locations with different occurrence of bacteria. If a source has an average bacterial count of 500 cfu / 100ml, 0.2 ml will usually give a positive test. By injecting about half of this volume, you will often get both positive and negative samples. If the source has lower concentrations of bacteria, the media concentration can be changed so that the sample volume can be as high as 10 ml. In this way, we ensure good results from the CALM instrument with optimal concentration of media after addition of sample and a sample volume appropriate for the source being measured.
  • Colifast
    Colifast Field Kit is a portable tool for field detection of coliform bacteria in water. The main method of the kit is a rapid method that provides an answer as early as 15 minutes, 2 hours at the latest. In addition, the kit includes methods for a quantitative MPN (Most Probable Number) method and presence/absence results. The procedure is very easy to perform, and requires no laboratory skills. Colifast Field Kit is delivered in a robust and portable metal case, and all equipment required for the water analysis is included. The Colifast Micro Detector (CMD) is used in combination with a growth medium for specific detection of target bacteria. Combined, they provide a simple instrumental analysis and rapid results that quantify the amount of coliform and thermotolerant bacteria in water. The method is based upon the patented technology of Colifast AS. The system detects down to 1 target bacterium per sample volume. Method The Colifast technology is based on a chemical reaction between a substrate in the growth medium and enzymes produced by the coliform bacteria. The bacterial enzyme β-D-galactosidase hydrolyses the substrate 4-methylumbelliferyl-β-D-galactoside, which results in the release of the fluorescent product 4-methylumbelliferone (MU). In addition to substrate, activators and growth factors, the medium comprises inhibitors that prevent the growth of non-coliform bacteria. The results are measured in fluorescent units. An increase in the number of bacteria corresponds to an increased amount of β-D-galactosidase (enzyme). The subsequent increase in the amount of MU (fluorescent product) results in a higher value on the instrument (Colifast Micro Detector). The incubation temperature selects for thermotolerant coliforms at 44 °C and total coliforms at 37 °C.
  • Bentley Instruments
    Rapid & accurate determination of Somatic Cells and Chemical Composition in raw milk Automatic milk analysis at 600 samples/hour Engineered in accordance with Bentley Instruments’ rigorous design principles, the FTS combi provides precise and accurate measurements. The FTS combi comprises two separate modules — the Bentley Flow Cytometer (FCM), and the Bentley Fourier Transform Spectrometer (FTS). The FCM measures the somatic cell count of the milk samples while the FTS simultaneously measures the milk composition up to 64 parameters (fat, protein, lactose, casein, fatty acids profil, minerals, blood BHB,...). After first being stirred, the milk is drawn from a sample vial and delivered to both measurement modules. The sampling, sequencing and identification of the sample vials are functions performed by the Autosampler. 3M™ Clean-Trace™ Surface ATP UXL100 3M™ Clean-Trace™ Water Plus - Total ATP AQT200 3M™ Clean-Trace™ Water - Free ATP AQF100
  • Bentley Instruments
    Rapid and accurate determination of milk products chemical composition Semi-automatic and automatic versions from 100 up to 300 samples/hour The DairySpec FT uses FTIR spectroscopy for extremely accurate and reliable milk and dairy products chemical composition determination. Analysing up to 64 parameters simultaneously, the DairySpec FT is the optimal solution for the quality control of raw and processed materials. It gives access to the very fine analysis of milk and dairy products chemical composition (fat, proteins, casein, lactose, solids, urea, citric acid, fatty acids profil, FPD). Highly reliable and accurate for milk (raw, UHT, ...) and dairy products (cream, whey, permeate, retentate, ...) analysis. Adaptable to measure other products and parameters upon request. The spectra are standardised in real time to optimise calibrations transferability, stability and qualitative analysis (adulteration). Direct access to spectra for the development of new calibrations. 3M™ Clean-Trace™ Surface ATP UXL100 3M™ Clean-Trace™ Water Plus - Total ATP AQT200 3M™ Clean-Trace™ Water - Free ATP AQF100
  • Bentley Instruments
    Simultaneous Somatic Cell and Component Analysis Automatic versions from 100 up to 300 samples/hour System that combines the DairySpec FT for component analysis and the SomaCount FC for Somatic Cell Counting. The combination of these two flagship methods provides a complete overview of milk chemical and hygienic composition by analysing up to 64 parameters simultaneously. Different versions of DairySpec Combi are available (100, 150, 200, 250, 300) up to a maximum speed of 300 samples/hour. The sampling, sequencing and identification of the sample vials are functions performed by the Autosampler. Compatible with the ILAS 3000 ROBOT: Automation System for Milk Analysers
  • Stratix Labs - Sample Sampling Competency Enverify™ 100 PV Kit
    Hands-on training & performance verification improves pathogen detection. Data collected from environmental sampling of surfaces is highly dependent on the operator. Understanding and quantitatively characterising the percent recovery and consistency of sample collection by an operator drives improved detection and prevention of pathogens. Performance verification involves determining the percent recovery and consistency of an operator who collects samples in an environmental sampling program. Introducing Enverify™, a quantitative positive control for environmental sampling programs and comprises a flat substrate with a specific quantity of viable microorganisms coated on the surface. The microbes are safe-to-handle and are coated across a 10 cm x 10 cm area. Enverify™ provides a standardised tool for hands-on training and performance verification of operators that collect samples in environmental sampling programs. Enverify™ is compatible with contact plates, swab sampling devices, and sponge sample devices. Activities Involving Environmental Sampling:
    • Environmental monitoring for pathogens or indicator organisms
    • Sanitation verification using ATP or indicator organisms
    • Verification of hygienic restoration following adverse events
    • Verification of containment during construction activities
  • Biotecon Diagnostics
    Environmental testing and water quality control are a major concern for public health and are subject to laws and regulations in many countries. Water-bearing systems contaminated with pathogens are a source of infection and must be tested. BIOTECON Diagnostics’ real-time PCR-based microproof® LyoKits play a trusted role in detection and quantification of pathogens in environmental samples and water, and offer reliable analysis with high sensitivity and specificity.
  • Biotecon Diagnostics
    A pathogen is a synonym for a disease-causing microorganism. Food pathogens represent a special form of microbial pathogens, which are picked up and spread through food. Below a number of pathogens are listed, for which BIOTECON Diagnostics offers suitable foodproof® DNA extraction and real-time PCR detection kits. Many of the pathogen kits have been certified by recognized institutions such as AOAC-RI, MicroVal or NordVal (see licensing options / validations), and thus independently tested for quality and safety.
  • Biotecon Diagnostics
    Foodborne viruses can cause various, sometimes serious conditions. Contamination of food and bottled water is usually through infected persons or contaminated waste water. Viruses can not reproduce on food or in water, but small amounts of residing viruses may be sufficient to cause infection. The standard method for virus detection in food and water samples is PCR. BIOTECON Diagnostics offers a Hepatitis A virus kit, a norovirus real-time PCR kit and a new multiplex system for both virus particles specifically for the investigation of food. All kits contain a ready-to-use Process Control solution. With each sample you can detect a Process Control (MS2-phage in our case).
Go to Top